Input Table :
| Model |
Input
Range |
Input
Current |
|
ACE-828A/830AP |
90 ~ 130V AC or 180 ~ 260V AC, 47 ~
63Hz ( Auto-Switch ) |
|
|
ACE-828C |
+18 ~ +32V DC |
5A@24V DC |
|
ACE-828T |
-40 ~ 72V DC |
10A@-48V
DC |
-
Output Table : ( at
40oC )
|
Model |
Rated
Load |
Max
Output |
| +5V |
+12V |
-12V |
-5V |
+3.3V |
+5Vsb |
+5V |
+12V |
-12V |
-5V |
+3.3V |
+5Vsb |
|
ACE-830AP |
30A |
6A |
0.5A |
0.5A |
1A |
1A |
35A |
10A |
1A |
1A |
20A |
1.5A |
|
ACE-828A |
25A |
10A |
0.5A |
0.5A |
8A |
0.72A |
30A |
15A |
2A |
1A |
15A |
1.2A |
|
ACE-828C |
25A |
7A |
1A |
0.5A |
8A |
0.72A |
30A |
15A |
2A |
1A |
15A |
1.2A |
|
ACE-828T |
25A |
7A |
1A |
0.5A |
8A |
0.72A |
30A |
15A |
2A |
1A |
15A |
1.2A |
-
Ripple and Noise
: Less than 50mV@+5V and +3.3V; 100mV@Others
-
Line Regulation : The
line regulation for each outputs are less than +/-1%
-
Load Regulation
:
|
Model |
+5V |
+12V |
-12V |
-5V |
+3.3V |
+5Vsb
|
|
ACE-830AP |
<+/-1% |
<+/-1% |
<+/-1% |
<+/-1% |
<+/-1% |
<+/-1% |
|
ACE-828A |
<+/-3% |
<+/-5% |
<+/-2% |
<+/-2% |
<+/-2% |
<+/-3% |
|
ACE-828C |
<+/-3% |
<+/-5% |
<+/-2% |
<+/-2% |
<+/-2% |
<+/-1% |
|
ACE-828T |
<+/-3% |
<+/-5% |
<+/-2% |
<+/-2% |
<+/-2% |
<+/-1% |
-
Output Power : Total
Combined output power on the +3.3V and +5V rails is 150W
-
Efficiency : Higher than
65%
-
Hold-up Time ( ACE-828A/830AP ) : 20ms (typical)@115V AC
-
Altitude : 0 ~
10,000ft
-
Protection :
--> Over
voltage protection : The trip point is around 5.7V ~ 7.0V
output
--> Short circuit protection
-
Vibration : 10 ~ 55Hz at 2G
3min. period, 30min. along X, Y and Z axis
-
Impact : 10G for 20ms once
on each X, Y and Z axis
-
Built-in ball bearing cooling
fan
-
MTBF :
-->
ACE-828A : 101,379 Hours
-->
ACE-828C : 121,233 Hours
-->
ACE-828T : 112,112 Hours
-
Safety : Meets UL 1950; CSA
22.2 No. 234, VDE EN 60 950
-
EMI :
--> Meets FCC
class "B", EN55022 class "B"
--> Harmonic EN 61000-3-2 for
ACE-830AP
-
EMS Standard ( Design to meet
the following limits ) :
--> IEC 801-2 8KV ( Air
Discharge )
--> IEC 801-3, 3V/M criteria A
--> IEC
801-4, 2KV criteria B
--> IEC 801-5, 2KV criteria B
-
Operating Temperature :
-20o ~ 70oC ( Derating curve will occur
40o ~ 70oC)
-
Storage Temperature :
-40o ~ 75oC