Features
- PICMG 2.11 CompactPCI Power Interface compliant
- 3U CompactPCI 8HP form factor
- PICMG 2.11 47-pin CompactPCI in-rack power module interface
- 250 W DC output
- Active PFC (Power Factor Correction) meets IEC1000-3-2 Harmonic Correction
- Internal OR-ing Diodes for N + 1 redundancy
- Hot swappable
- Active current sharing
- EMI meets EN 55022 & FCC Class A
- Supports remote ON/OFF
- Supports power failure signal & degradation signal
- PICMG Standards: PICMG 2.11 CompactPCI Power Interface compliant
- Form Factor: 3U cPCI (100 x 160mm), 2-slot (8HP) wide
- Input Voltage: 100 ~ 240 Vac ±10%
- Input Frequency: 50 ~ 60 Hz ±5%
- Input Current: 1.4 A @ 230 Vac
- Inrush Current: <30 A @ 230 Vac
- Power Factor (PFC, only for AC):
• Correction Typical 0.95-0.97
• Meets Harmonic Correction IEC1000-3-2 - Output Voltage/Current:
• 5 V: Typ. 25.0 A, Max. 33.0 A
• 3.3 V: Typ. 18.0 A, Max. 33.0 A
• +12 V: Typ. 5.0 A, Max. 5.5 A
• -12 V: Typ. 0.5 A, Max.1 A
• Max. load is the continuous operating load of each rail individually.
• The max. load of each rail cannot be drawn from all outputs simultaneously. - Output Voltage: 0.5 A @ +5 V - Minimum Load
- Output Wattage: Typical 250 W continuous
- Line Regulation: Typical 0.1%
- Load Regulation: Typical ± 1-2%
- Ripple:
• 50 mV @ +5 V and 3.3 V outputs
• 120 mV @ +12 V and -12 V outputs - Hold-up Time: 5 ms after power fail signal
- Efficiency: Typical 78-79%
- Output voltage sense: Available at 5 V, 3.3 V, and +12 V outputs and current sharing
- N+1 Redundancy: Equipped with internal OR-ing diodes at all outputs for N+1 redundancy operation
- Remote ON/OFF: Available at [INH#] & [EN#]
- Power Failure Signal: Available at [FAL#] pin
- Power Degradation Signal: Available at [DEG#] pin
- Protections:
• Over Temperature Protection (OTP): 70˚C
• Over Current Protection (OCP): Installed at each rail
• Over Load Protection (OLP): Typical 120% max. load, fully protected against output overload or short circuit.
• Over Voltage Protection (OVP): Built-in at all outputs - Status LED:
•: [POWER] means valid input voltage
•: [FAULT] means a critical fault - Earth Leakage: <0.5 mA @ 230 Vac
- Operating Temp.: 0 ~ +70˚C
(0 ~ +50˚C at full load with specified air flow. Derates linearly to 50% at +70˚C.) - Storage Temp.: -40 ~ +85˚C
- Humidity: 5 ~ 95% non-condensing
- Shock: 15 G peak-to-peak, 11 ms duration, non-operation
- Vibration:
• Operation: 1.88 Grms, 5 ~ 500 Hz, each axis - Cooling Requirement: Min. 20 CFM is required for typical full power rating
- Certifications: IEC950, EN 55022, FCC Class A, IEC60950 Class I
- cPS-H325/AC - PICMG 47-pin hot-swap redundant 3U CompactPCI 8HP 250 W power module with universal AC Input