cPS-H325/24

  • Zasilacz redundancyjny hot-swap 3U cPCI 8HP 250 W z wejściem 18 ~ 36 Vdc
  • cPS-H325/24
Features
  • PICMG 2.11 CompactPCI Power Interface compliant
  • 3U CompactPCI 8HP form factor
  • PICMG 2.11 47-pin CompactPCI in-rack power module interface
  • 250 W DC output
  • Internal OR-ing Diodes for N + 1 redundancy
  • Hot swappable
  • Active current sharing
  • EMI meets EN 55022 & FCC Class A
  • Supports remote ON/OFF
  • Supports power failure signal & degradation signal
Specifications
  • PICMG Standards: PICMG 2.11 CompactPCI Power Interface compliant
  • Form Factor: 3U cPCI (100 x 160mm), 2-slot (8HP) wide
  • Input Voltage: 18 ~ 36 Vdc
  • Input Frequency: DC
  • Input Current: 14A @ 24 Vdc
  • Inrush Current: N/A
  • Output Voltage/Current:
    • 5 V: Typ. 25.0 A, Max. 33.0 A
    • 3.3 V: Typ. 18.0 A, Max. 33.0 A
    • +12 V: Typ. 5.0 A, Max. 5.5 A
    • -12 V: Typ. 0.5 A, Max.1 A
    • Max. load is the continuous operating load of each rail individually.
    • The max. load of each rail cannot be drawn from all outputs simultaneously.
  • Output Voltage: 0.5 A @ +5 V - Minimum Load
  • Output Wattage: Typical 250 W continuous
  • Line Regulation: Typical 0.1%
  • Load Regulation: Typical ± 1-2%
  • Ripple:
    • 50 mV @ +5 V and 3.3 V outputs
    • 120 mV @ +12 V and -12 V outputs
  • Hold-up Time: 5 ms after power fail signal
  • Efficiency: Typical 78-79%
  • Output voltage sense: Available at 5V, 3.3V, and +12V outputs and current sharing
  • N+1 Redundancy: Equipped with internal OR-ing diodes at all outputs for N+1 redundancy operation
  • Remote ON/OFF: Available at [INH#] & [EN#]
  • Power Failure Signal: Available at [FAL#] pin
  • Power Degradation Signal: Available at [DEG#] pin
  • Protections:
    • Over Temperature Protection (OTP): 70˚C
    • Over Current Protection (OCP): Installed at each rail
    • Over Load Protection (OLP): Typical 120% max. load, fully protected against output overload or short circuit.
    • Over Voltage Protection (OVP): Built-in at all outputs
  • Status LED:
    : [POWER] means valid input voltage
    : [FAULT] means a critical fault
  • Earth Leakage: <0.5 mA @ 24 Vdc
  • Operating Temp.: 0 ~ +70˚C
    (0 ~ +50˚C at full load with specified air flow. Derates linearly to 50% at +70˚C.)
  • Storage Temp.: -40 ~ +85˚C
  • Humidity: 5 ~ 95% non-condensing
  • Shock: 15 G peak-to-peak, 11 ms duration, non-operation
  • Vibration:
    • Operation: 1.88 Grms, 5 ~ 500 Hz, each axis
  • Cooling Requirement: Min. 20 CFM is required for typical full power rating
  • Certifications: IEC950, EN 55022, FCC Class A, IEC60950 Class I
Ordering Information
  • cPS-H325/24 - PICMG 2.11 47-pin hot-swap redundant 3U CompactPCI 8HP 250 W power module with 18 ~ 36 Vdc Input

 

Jeśli potrzebujesz dodatkowych informacji zadzwoń do nas (22 831 10 42) lub napisz wiadomość. 

Gwarancja 24 miesiące - Gwarancja udzielana przez sprzedawcę na okres 24 miesięcy.

Gwarancja standardowa 24 miesiące

Opinie użytkowników
Zapytaj o produkt:

Jeżeli powyższy opis jest dla Ciebie niewystarczający, prześlij nam swoje pytanie odnośnie tego produktu. Postaramy się odpowiedzieć tak szybko jak tylko będzie to możliwe.

E-mail:
To pole jest wymagane do złożenia zamówienia.
Pytanie:
To pole jest wymagane do złożenia zamówienia.
pola oznaczone - To pole jest wymagane do złożenia zamówienia. - są wymagane
pixel